ERW Pipe
Gas,Oil,Water transport,Pile and Construction and etc.
Outside Diameter ¢76mm-¢508mm
Wall Thickness 3.2mm-20mm
Grade X42-X70 J55、K55、H40
Standard API 5CT API 5L-PSL1 API 5L-PSL2 ASTM A53
QUALITY INDEX FOR LINE PIPE
SSAW Pipe
Gas,Oil,Water transport,Pile and Construction and etc.
Outside Diameter ¢219mm-¢2250mm
Wall Thickness 5mm-20mm
Grade X42-X70
Standard API 5L-PSL1 API 5L-PSL2
Item |
GB/T9711.1—1997 SSAW Pipe ERW Pipe |
GB/T9711.2—1999 SSAW Pipe ERW Pipe |
API 5L SSAW Pipe ERW Pipe |
SY/T5037-2000 SSAW Pipe |
||
Dia.of ends variation |
OD≤273.1mm +1.59mm -0.04mm 323.9mm≤OD≤508mm +2.38 -0.79mm OD>508mm +2.38mm -0.79mm |
OD≤610mm ±0.5mm或±0.5% OD 610mm<OD≤1430mm ±1.6 mm OD>1430mm |
+2.38mm -0.79mm |
OD<508mm ±0.75% OD OD≥508mm ±1.00% OD |
||
Thickness variation |
|
OD<508mm +15.0%t, -12.5%t OD≥508mm +17.5%t, -10.0%t (L175、L210、L245) +19.5%t, -8.0%t (L290-L555) |
T≤10mm, +1.0mm -0.5mm
10mm<T<20mm+10% -5% T≥20mm, +2.0mm -1.0mm |
OD<457mm +15.0%t -12.5%t OD≥508mm +19.5%t -8.0%t |
OD<508mm ±12.5%t OD≥508mm ±10.0%t |
|
|
||||||
Ellipticity variation |
|
OD≥508mm, ±1.00% OD
|
60mm<OD≤610mm,1.5% OD
|
OD≥508mm ±1.00%D |
±1.00%OD
|
|
Straight-ness |
|
≤0.2%L |
≤0.2%L |
<0.2%L |
≤0.2%L |
|
Ends
Weight Variation |
|
ends beveled 30° -35° root face 1.59±0.79mm cut square1.59mm
unit+10%,-3.5% partial delivered -1.75% Based on the theoretical weight |
ends beveled 30° -35° root face 1.6±0.8mm cut square≤1.6mm
unit+10%,-3.5% |
ends beveled 30° -35° root face 1.59±0.79mm cut square1.59mm
unit+10%,-3.5% partial delivered-1.75% |
ends beveled 30° -35° root face 1.6±0.8mm cut square D<813mm,<1.5m D≥813m,<3.0mm Based on the theoretical weight or as discuss between buyer and seller |
|
Non-destr-uctive test |
|
100%X-ray inspection or 100% ultrasonic and X-ray inspection for ends |
100%X-ray inspection or 100% ultrasonic and X-ray inspection for ends |
100%X-ray inspection or 100% ultrasonic and X-ray inspection for ends |
The patching welded joint, the butt-welded seam and the link to the welded joint, should make the X-ray or the ultrasonic testing. |
|
Hydrostat-ic tests |
|
P=2st/D L210、L245、S=0.6σ0.5 L290-L555 D=219。1MM,s=0.75σ0.5 D=273.1mm -457mm, s=0.85σ0.5 D≥508mm,S=0.9σ0.5 Steady time for pressure≥10S |
P=2st/D S=95%σ0.5 D=≤406.4mm P≤50Mpa D>406.4mm P≤25Mpa Steady time for pressure≥10S
|
P=2st/D D<508mm S=0.85σ0.5 D≥508mm S=0.9σ0.5 Steady time for pressure≥10S
|
P=2st/D S=60%σ0.5 D≤508mm Steady time for pressure≥5S D≥508mm Steady time for pressure≥10S |
|